The system zeropoint is the brightness anchor of your rig: the magnitude of a star that would deliver exactly one electron per second through your telescope, filter and camera. The Exposure Calculator’s exoplanet mode scales every prediction from it. Out of the box it uses a theoretical value, which field tests showed can be about 40× optimistic – so before you trust an exoplanet exposure, spend ten minutes measuring a few stars in one of your own subs. This article walks through it.
Why Calibrate #
- A measured zeropoint folds in everything the theory cannot know: real aperture and obstruction, coating and filter throughput, sensor QE, and typical extinction at your site.
- The Exposure Calculator shows the difference plainly: an uncalibrated filter carries the banner ⚠ Theoretical zeropoint (~40× optimistic) – calibrate this filter for a trustworthy exposure; a calibrated one reads ✓ measured.
- Zeropoints are stored per filter (your equipment filter on that telescope) and also as a shared band fallback (L, R, G, B, Ha, IR and so on) for filters and rigs you have not calibrated yet.
Tip: Calibration matters for Exoplanet Mode only. The Target SNR forecast deliberately ignores measured zeropoints – see the last section.
What You Need #
- A FITS light sub (
.fit,.fits,.ftsor.fz) straight from the camera – raw ADU, not stretched or stacked. XISF and common image formats can be annotated but not calibrated. EXPTIMEin the header (required) andEGAIN(e⁻/ADU). IfEGAINis missing – photometry tools such as HOPS and EXOTIC strip it – you are asked for your camera’s gain at that capture’s gain setting, and the value is remembered for the session.- The sub must be taken through the filter you want to calibrate, on the telescope you want to calibrate.
- Several clean, isolated, unsaturated stars with catalog magnitudes – ideally 5-8 spanning a few magnitudes.
Step by Step #
- Open the sub in Image Annotator (or click Calibrate… next to the System Zeropoint in the Exposure Calculator, which opens the Annotator).
- Plate solve it with ASTAP or astrometry.net.
- Make sure a star catalog is ticked in CATALOGS, then Fetch Catalogs & Annotate.
- Tick Highlight calibration stars. Lime rings mark isolated stars between magnitude 8 and 13 – the easiest good candidates.
- Click a ringed star’s label and press + Calibrate on its info card. Astro PM measures the star’s background-subtracted flux in your frame (aperture photometry at native resolution) and opens the calibration window with the star added.
- Repeat for more stars. Each one’s colour and temperature is fetched from Gaia and its variability flag from SIMBAD in the background.
- Check the filter under Store for filter:, review the table, then press Save Zeropoint.
The Calibration Window #
The line at the top states the frame context: Filter, Exposure, EGAIN, camera and telescope from the header. If every pixel value in the file is a multiple of 4 or 16, the camera delivered a 14- or 12-bit ADC as 16-bit data; the header’s EGAIN is per native ADU, so Astro PM divides it accordingly and says so (EGAIN: 1.0 ÷ 16 = 0.0625 e⁻/ADU (12-bit data stored ×16)). Without this correction the zeropoint would read about 3 magnitudes too bright.
Store for filter: lists your equipment filters with their brand and telescope. It is pre-selected from the frame’s
FILTER and TELESCOP headers – change it if the guess is wrong. Band only stores just the shared fallback for that band. The selected filter’s centre wavelength (when set in Equipment) drives the colour transform. | Column | Meaning |
|---|---|
| Use | Untick to exclude a star from the fit. |
| Star, V | Catalog name and magnitude. |
| Type | Spectral class from Gaia’s colour/temperature. Type a class letter (O, B, A, F, G, K, M) to override it. |
| e⁻/s | Measured electrons per second from the star. |
| ZP | The zeropoint this star implies after the colour transform into your band. |
| Note | saturated (excluded automatically), outlier (clipped from the mean), variable! (SIMBAD flags it – consider unticking), set type (no colour found – enter a class). |
Below the table the result updates live: Zeropoint = 19.52 ±0.21 mag (7 stars) · FWHM ≈ 2.6″. The mean is robust: stars more than 2.5σ (median absolute deviation, never tighter than 0.6 mag) from the median are flagged as outliers and left out. Clear empties the list and starts over; Close closes the window and discards the list, so save first. If you add a star from a frame with a different filter you are warned – zeropoints are per band, so Clear and start over.
Save Zeropoint stores the value for the selected filter and updates the band fallback, together with the measured FWHM (which then seeds the calculator’s seeing box) and the telescope’s aperture.
Using the Zeropoint in the Exposure Calculator #
In exoplanet mode the filter list marks calibrated entries: ✓ calibrated means that filter has its own measurement; ✓ band ZP means it would borrow the shared band value. The System Zeropoint row tells you which value is in use:
| Label | Meaning |
|---|---|
| theoretical | No measurement for this band – the banner warns you. |
| ✓ measured (N★) | Measured for this filter on this telescope from N stars. |
| ✓ band X (N★) | This filter has no zeropoint of its own, so the shared band value is used. Same-band filters from different makers differ by tenths of a magnitude – calibrate a sub through this filter to store its own. |
| ✓ scaled D1″→D2″ (N★) | Measured on a different telescope and rescaled by collecting area (+5·log₁₀(D₂/D₁)). Throughput differences between the scopes are not captured, so calibrate on this telescope when you can. |
When the calculator is opened from the Exoplanets planner it also prefers a band you have calibrated, so you are not dropped back onto a theoretical value.
Why Target SNR Mode Ignores Calibrations #
A star calibration measures a point source’s light. Applied to an extended nebula or galaxy, it overstates the required integration time enormously (around 100× in testing). The Target SNR forecast therefore always uses the theoretical zeropoint for both the target and the sky, so the contrast between them – which is what drives the answer – stays consistent.
Tip: Recalibrate after anything that changes throughput: a new filter, a cleaned or re-coated mirror, a different camera, or a reducer added to the train.