Transit photometry inverts the deep-sky problem. You are measuring one bright star to a precision of a few parts per thousand, so the sub length has to keep the star safely linear, sample the transit’s ingress and egress, and squeeze the most total signal out of the event. The Exposure Calculator’s Exoplanet Star (point source) mode plans all of that – and simulates the light curve you should expect. The mode is labeled in development: the model is validated against real transits but still being refined. Shared inputs (equipment, gain mode, sky, binning, bias) are described in Exposure Calculator.
Opening It From a Transit #
The quickest way in is the Calc button on a row in Framing > Exoplanets (Exoplanet Targets & Transit Planning). It switches the calculator to exoplanet mode and fills in:
- Telescope and camera from the planner’s imaging system.
- Star Magnitude (V) – converted to a V equivalent when the catalog only has a TESS, Gaia G or R magnitude (TESS magnitudes are typically 0.5-1 mag brighter than V).
- Spectral Type from the host star’s temperature.
- Filter – the R band (ExoClock’s standard), or Luminance for stars fainter than magnitude 13; but a band you have calibrated always wins, and your own equipment filter of that band is preferred over the generic entry.
- Airmass from the altitude at mid-transit.
- The transit duration and depth, which drive the cadence cap, the Target SNR and the light-curve simulation.
A banner names the loaded target; its ✕ clears the label (the numbers stay). Loading a new target returns Cadence Cap and Target SNR to automatic. You can also pick the mode by hand and type the star’s values – without a target the calculator assumes a mid-range ingress.
Inputs #
| Input | Default | What it does |
|---|---|---|
| Star Magnitude (V) | 10.0 | Apparent V magnitude of the host star. The spectral type transforms it into your filter’s band. |
| Well Fill Cap (%) | 50 | The linearity ceiling: the recommended sub never puts the star’s brightest pixel above this fraction of full well. A cap, not a goal – the sub does not need to reach it. Lower it if your sensor goes non-linear early. |
| Target SNR (per point) | auto (400 with no target) | A per-point quality check: SNR = 1086 ÷ (depth/3), never below 20 – i.e. scatter of a third of the transit depth. Type a value to demand a per-point SNR; the sub lengthens (up to the linearity ceiling) to reach it. Manual values stick until you load a new target. |
| Cadence Cap (pts) | auto: 4 | Points needed across the limb-crossing (ingress or egress). The sub is never longer than limb-crossing ÷ this. Type a value to take manual control. |
| Optical Throughput | 0.70 | Coatings, obstruction and filter glass, 0-1. ~0.7 for a refractor, lower for an obstructed reflector. Folded into the theoretical zeropoint. |
| Airmass | 1.2 | 1.0 at zenith, ~1.4 at 45°, ~2.0 at 30°. |
| Extinction (mag/X) | 0.15 | Dimming per airmass; ~0.15 in V at a good site, more in blue and in haze. |
| Spectral Type | G | O (~35000 K) to M (~3300 K). A red K/M star is brighter in Red than its V implies; A is the colour-neutral reference. |
| Noise Factor (×) | 1.0 | Multiplies the predicted noise to cover systematics photon maths cannot see (see below). |
In this mode the sky section notes that sky brightness barely affects a bright star’s exposure – FWHM is the key seeing input, because it sets how much of the star lands on the peak pixel.
Careful: Set Binning to match how you actually image: a binned pixel collects more of the star’s peak and fills faster, so 2×2 subs need a shorter exposure. For transits, image at 1×1 if you can (AAVSO guidance) – CMOS binning happens after readout, so a physical pixel can clip while the binned value looks safe. If the star is too bright, defocus rather than bin.
How the Recommended Sub Is Chosen #
Once ingress and egress are sampled, more points do not improve timing or depth – total transit SNR does (Carter et al. 2008). So the plan is:
- Efficiency – the shortest sub that keeps at least 95% of the best achievable total transit SNR. Short subs cost read noise and about 2 s of download per frame, so bright stars get short subs and faint, read-noise-limited stars get longer ones.
- Cadence cap – never longer than the limb-crossing time ÷ Cadence Cap.
- Linearity ceiling – never past the Well Fill Cap.
- Target SNR – if you typed a demanding Target SNR, extended (up to the ceiling) until it is reached.
Hover the recommended sub to see which rule set it (Efficiency, Cadence-capped, Linearity-capped or Extended to reach the Target SNR) and the total-SNR efficiency it achieves.
Reading the Results #
EXOPLANET RESULTS compares two columns: RECOMMENDED (the plan) and YOUR SUB (computed at the Sub-Exposure length you entered, with green or orange deltas showing whether your choice beats the plan). Change Sub-Exposure freely to explore – it never moves the recommendation.
| Row | Meaning |
|---|---|
| Sub Exposure | The recommended length, and your entered length. |
| Precision (per point) | Expected per-point scatter in millimagnitudes (scintillation included) versus the target scatter of depth ÷ 3. The dip must stand clear of this scatter. |
| Expected STD (residuals) | The same scatter in the units HOPS prints under a fitted light curve – parts per thousand (‰) of the star’s flux, with the percentage. This is the photon/read-noise/scintillation floor; real curves land higher. |
| Single Exposure SNR | Per-frame SNR, drawn as a gauge against the depth/3 floor. |
| Total Transit SNR | Detection significance of the whole transit (in σ), gauged on ExoClock’s tiers: ≥15 excellent, 10-15 good, 6-10 marginal (~6 is their minimum-telescope floor), <6 weak. |
| 1×1 Physical-Pixel Limit | The same well-fill target solved on the unbinned pixel – the true linearity ceiling whatever binning is selected. |
| Estimated Peak ADU | The brightest star pixel you should read off a sub, against the camera’s ADC maximum. A note appears if your gain maps the full well beyond what the ADC can record, or if the recommended sub already clips. |
| Star Flux (total), In-band mag (filter), Peak Pixel Rate | The star’s total e⁻/s, its magnitude in your band, and the e⁻/s on its brightest pixel. |
| System Zeropoint | The brightness anchor every number scales from, with its source (theoretical, measured, band, or scaled) and a Calibrate… button. |
On the gauges the recommended plan is a green ▲ under the bar and your sub an orange ▼ above it.
The Zeropoint Matters Most #
Careful: Until you calibrate, the banner reads ⚠ Theoretical zeropoint (~40× optimistic) – calibrate this filter for a trustworthy exposure. A too-optimistic zeropoint means a too-short sub and a noisier light curve than predicted. Click Calibrate… and follow Calibrating Your System Zeropoint – it takes a single plate-solved sub.
In the filter list, ✓ calibrated marks filters with their own zeropoint and ✓ band ZP those that would borrow a shared band value. A calibration also stores the FWHM measured on that frame, which seeds the FWHM box when you select the filter.
Chart Tabs #
| Tab | Chart | Use it to |
|---|---|---|
| Precision (default) | PER-POINT PRECISION vs SUB LENGTH, with the cadence and linearity caps and the transit depth you are chasing | See where the recommendation sits and how much precision a different sub length buys. |
| Light Curve | SIMULATED TRANSIT LIGHT CURVE – every planned sub with realistic scatter, a smooth limb-darkened fit and its recovered depth, for the plan and for your sub, each labeled with sub length, count and STD (‰ and mmag) | Preview what your submitted curve should look like before you spend the night. |
| Well Fill | PEAK PIXEL WELL FILL vs EXPOSURE, in ADU with the ADC clip line | Check linearity and saturation margins. |
| FWHM Table | RECOMMENDED EXPOSURE (s) – SEEING × MAGNITUDE: seeing 0.5-6.0″ down the side, star magnitude ±2 across the top | Plan for a soft or sharp night, or a slightly different star. Hover a cell for details. |
Calibrating the Noise Factor From Your Own Curves #
The prediction is a floor: photons, read noise and scintillation only. Real light curves add comparison-star noise (fewer or fainter comparison stars add more – a single comparison star can raise the scatter by half again), leftover airmass trends, guiding drift and thin cloud. Noise Factor scales the prediction to match your reality:
- Fit a transit you have observed in HOPS (or similar) and note its STD = … ‰.
- Set the calculator to that night’s setup and read Expected STD (residuals).
- Noise Factor = achieved STD ÷ Expected STD. Example: XO-6 b achieved 5.2‰ against ~1.8‰ predicted → about 2.9.
Use a typical night, not your worst. The factor applies to precision, Expected STD, both SNR gauges, the recommended sub and the simulated light curve. Slow correlated trends do not average down with more points, so Total Transit SNR stays somewhat optimistic when HOPS reports high autocorrelation.
Tip: Transits are broadband work: the dip is the same at all wavelengths, so narrowband filters only throw away photons. Rc/Red is ExoClock’s recommended band; use Luminance or Clear for faint hosts.